Mini-Split Service Training Handbook / Nejlevnější knihy
Mini-Split Service Training Handbook

Kód: 54215817

Mini-Split Service Training Handbook

Autor Ramon C. Roberts

Install it right, diagnose it with evidence, and repair it once.Ductless mini-split heat pumps now heat and cool millions of homes, additions, and small buildings, and every one of them combines line voltage, an inverter drive, a ... celý popis

880 Kč


Skladem u dodavatele
Odesíláme za 9-13 dnů
Přidat mezi přání

Mohlo by se vám také líbit

Darujte tuto knihu ještě dnes
  1. Objednejte knihu a zvolte Zaslat jako dárek.
  2. Obratem obdržíte darovací poukaz na knihu, který můžete ihned předat obdarovanému.
  3. Knihu zašleme na adresu obdarovaného, o nic se nestaráte.

Více informací

Více informací o knize Mini-Split Service Training Handbook

Nákupem získáte 88 bodů

Anotace knihy

Install it right, diagnose it with evidence, and repair it once.
Ductless mini-split heat pumps now heat and cool millions of homes, additions, and small buildings, and every one of them combines line voltage, an inverter drive, a DC bus that can stay charged, sensitive electronics, and a refrigerant circuit under pressure. Mini-Split Service Training Handbook is a full color field guide for the technicians who install and service them. It starts with how a ductless heat pump moves heat and ends with complete diagnostic case studies, with every step explained, illustrated, and tied to the manufacturer's data.

What you will learn

Inside the bookCurrent with the refrigerant transition
The book explains the move to lower-GWP refrigerants such as R-454B and R-32, the handling and tool requirements that come with A2L refrigerants, the SEER2 and HSPF2 ratings, and recent electrical code changes that affect outdoor HVAC equipment. Confirm the edition and local amendments that apply before relying on any rule.

Built around safe, evidence-based practice
Charge is judged from temperatures and pressures together at stable conditions, never from a single gauge reading. Refrigerant is never added simply because cooling is poor. Energized measurements are made only at the points the manufacturer specifies, by qualified technicians with rated meters, and no protective device is ever bypassed. Values that depend on the equipment, such as pressures, resistances, voltages, torques, line lengths, and fault codes, are given only as clearly labeled examples, so you learn the method and then apply it with the documents for the actual model.

Who it is for
HVAC apprentices and students, experienced technicians who are new to ductless and inverter equipment, electricians who wire mini-splits, and service managers who train their teams.

Parametry knihy

880 Kč



Osobní odběr Praha, Brno a 48283 dalších

Copyright ©2008-26 nejlevnejsi-knihy.cz Všechna práva vyhrazenaSoukromíCookies


Můj účet: Přihlásit se
Všechny knihy světa na jednom místě. Navíc za skvělé ceny.

Nákupní košík ( prázdný )

Vyzvednutí v Balikovně a PPL
boxech
zdarma nad 1 499 Kč.

Nacházíte se: