Direct charge collection measurements are presented which prove that the presence of tungsten near sensitive volumes leads to extreme charge collection events through nuclear reactions. We demonstrate that, for a fixed incident pa ... celý popis
Nákupem získáte 151 bodů
Direct charge collection measurements are presented which prove that the presence of tungsten near sensitive volumes leads to extreme charge collection events through nuclear reactions. We demonstrate that, for a fixed incident particle linear energy transfer (LET), increasing particle energy beyond a certain point causes a decrease in nuclear reaction-induced charge collection. This suggests that a worst-case energy exists for single-event effect susceptibility, which depends on the technology, device layout, and the incident ions fixed LET value. A Monte Carlo approach for identifying the worst-case energy is applied to certain bulk-Si and silicon-on-insulator technologies. Simulation results suggest that the decrease in charge collection beyond the worst-case energy occurs because the secondary particles produced from the high-energy nuclear reactions have less mass and higher energy and are therefore less ionizing than those produced by lower-energy reactions.