Microautoradiography and Electron Probe Analysis / Nejlevnější knihy
Microautoradiography and Electron Probe Analysis

Kód: 06805498

Microautoradiography and Electron Probe Analysis

Autor U. Lüttge

In biological literature, several definitions of quantitative autoradio graphy are given. The term is defined as either the determination and com parison of the density of silver grains above various structures or under varying co ... celý popis

2646


Skladem u dodavatele v malém množství
Odesíláme za 13-18 dnů

Potřebujete více kusů?Máte-li zájem o více kusů, prověřte, prosím, nejprve dostupnost titulu na naši zákaznické podpoře.


Přidat mezi přání

Mohlo by se vám také líbit

Dárkový poukaz: Radost zaručena

Objednat dárkový poukazVíce informací

Více informací o knize Microautoradiography and Electron Probe Analysis

Nákupem získáte 265 bodů

Anotace knihy

In biological literature, several definitions of quantitative autoradio graphy are given. The term is defined as either the determination and com parison of the density of silver grains above various structures or under varying conditions, or the determination of absolute quantities of radio activity. In both these cases, photometric measurement serves for more rapid and more exact evaluation of grain densities than would be possible by visual counting of the grains. The equipment generally used for the photometric measurement of silver grains consists of a microscope, a photocell, an electronic amplifier system and a display unit. Grains can be made accessible to photometric evaluation by various kinds of microscopic illumination: 1. Substage bright-field illumination. 2. Substage dark-field illumination. 3. Incident dark-field illumination. 4. Vertical bright-field illumination. With all these types of illumination, the relationship between the luminous flux I absorbed by the film, scattered into the objective and reflected or diffracted, and the flux 10 which is not affected by the film is used as a measure of grain density. Since these are differential measurements, the light beam I transmitted by the film is in itself a measure of grain density if the luminous flux 10 incident on the grains is kept constant. This approach has been used in a large number of measuring setups.

Parametry knihy

Zařazení knihy Knihy v angličtině Medicine Medicine: general issues Medical equipment & techniques

2646

Oblíbené z jiného soudku



Osobní odběr Praha, Brno a 46611 dalších

Copyright ©2008-26 nejlevnejsi-knihy.cz Všechna práva vyhrazenaSoukromíCookies


Můj účet: Přihlásit se
Všechny knihy světa na jednom místě. Navíc za skvělé ceny.

Nákupní košík ( prázdný )

Vyzvednutí v Balikovně a PPL
boxech
zdarma nad 1 499 Kč.

Nacházíte se: