Mass Transfer in Electrical Insulation of Power Transformers / Nejlevnější knihy
Mass Transfer in Electrical Insulation of Power Transformers

Kód: 04334105

Mass Transfer in Electrical Insulation of Power Transformers

Autor Ahmad Shahsiah

Dissolved Gas Analysis is one of the best known §methods to detect incipient faults in power §transformers. Characteristic gases for power §transformers are defined in IEC 60599. However, §these gases migrate between the transform ... celý popis

1506


Skladem u dodavatele
Odesíláme za 14-18 dnů
Přidat mezi přání

Mohlo by se vám také líbit

Darujte tuto knihu ještě dnes
  1. Objednejte knihu a zvolte Zaslat jako dárek.
  2. Obratem obdržíte darovací poukaz na knihu, který můžete ihned předat obdarovanému.
  3. Knihu zašleme na adresu obdarovaného, o nic se nestaráte.

Více informací

Více informací o knize Mass Transfer in Electrical Insulation of Power Transformers

Nákupem získáte 151 bodů

Anotace knihy

Dissolved Gas Analysis is one of the best known §methods to detect incipient faults in power §transformers. Characteristic gases for power §transformers are defined in IEC 60599. However, §these gases migrate between the transformer liquid §and solid insulation due to temperature variations; §this could potentially cause errors in the fault §detection method. Little analytical or experimental §work has been performed to date on the temporal §nature of this problem.§§The suggested dynamic model in this book is based on §the process of diffusion. The steady-state §information extracted from experiments is compared §with findings obtained from the literature. The §final dynamic model is tested against experiments.§§The results show that the migration phenomenon in §the liquid-solid insulation of power transformers §can be explained by diffusion equations. Other §findings include diffusion coefficients and steady-§state information of the characteristic gases in the §transformer insulation system. This text is suitable §for researchers who work in the area of fault §detection in high voltage fluid-filled equipment or §students who are interested in mass transport §phenomena. Dissolved Gas Analysis is one of the best known §methods to detect incipient faults in power §transformers. Characteristic gases for power §transformers are defined in IEC 60599. However, §these gases migrate between the transformer liquid §and solid insulation due to temperature variations; §this could potentially cause errors in the fault §detection method. Little analytical or experimental §work has been performed to date on the temporal §nature of this problem.§The suggested dynamic model in this book is based on §the process of diffusion. The steady-state §information extracted from experiments is compared §with findings obtained from the literature. The §final dynamic model is tested against experiments.§The results show that the migration phenomenon in §the liquid-solid insulation of power transformers §can be explained by diffusion equations. Other §findings include diffusion coefficients and steady-§state information of the characteristic gases in the §transformer insulation system. This text is suitable §for researchers who work in the area of fault §detection in high voltage fluid-filled equipment or §students who are interested in mass transport §phenomena.

Parametry knihy

Zařazení knihy Knihy v angličtině Technology, engineering, agriculture Energy technology & engineering Electrical engineering

1506

Oblíbené z jiného soudku



Osobní odběr Praha, Brno a 12903 dalších

Copyright ©2008-24 nejlevnejsi-knihy.cz Všechna práva vyhrazenaSoukromíCookies


Můj účet: Přihlásit se
Všechny knihy světa na jednom místě. Navíc za skvělé ceny.

Nákupní košík ( prázdný )

Vyzvednutí v Zásilkovně
zdarma nad 1 499 Kč.

Nacházíte se: