Effect of flow diverting stents on intracranial artery bifurcations with a focus on bifurcating vessels diameter on hemodynamics and occlusion / Nejlevnější knihy
Effect of flow diverting stents on intracranial artery bifurcations with a focus on bifurcating vessels diameter on hemodynamics and occlusion

Kód: 02890682

Effect of flow diverting stents on intracranial artery bifurcations with a focus on bifurcating vessels diameter on hemodynamics and occlusion

Autor Sarthak Khandelwal

Bachelor Thesis from the year 2015 in the subject Engineering - Mechanical Engineering, grade: 69%, University of Sheffield, language: English, abstract: An intracranial aneurysm is a vascular disorder estimated to affect up to 5% ... celý popis

1489


Skladem u dodavatele
Odesíláme za 14-18 dnů
Přidat mezi přání

Mohlo by se vám také líbit

Darujte tuto knihu ještě dnes
  1. Objednejte knihu a zvolte Zaslat jako dárek.
  2. Obratem obdržíte darovací poukaz na knihu, který můžete ihned předat obdarovanému.
  3. Knihu zašleme na adresu obdarovaného, o nic se nestaráte.

Více informací

Více informací o knize Effect of flow diverting stents on intracranial artery bifurcations with a focus on bifurcating vessels diameter on hemodynamics and occlusion

Nákupem získáte 149 bodů

Anotace knihy

Bachelor Thesis from the year 2015 in the subject Engineering - Mechanical Engineering, grade: 69%, University of Sheffield, language: English, abstract: An intracranial aneurysm is a vascular disorder estimated to affect up to 5% of the global population. The use of flow diverting stents for treatment of intracranial aneurysms leads to ischemic complications. It is hypothesized that alteration in hemodynamics after placement of stents plays a vital role in ischemia (vessel occlusion). This project uses Computational Fluid Dynamics to study the alterations in hemodynamics before and after placement of stent with respect to the relative diameter of the bifurcating arteries on idealized geometries using ANSYS-CFX 15.0. Pressure and flow rate waveforms were extracted from a 1D model of the arterial tree to simulate hemodynamic conditions correctly. The results show that there are significant changes in hemodynamics (pressure and wall shear stress) before and after placement of stent. These changes are also affected by the relative diameters of the bifurcating arteries. The trends observed in hemodynamics can be interpreted by clinicians to study vessel occlusion and its relation to the relative diameters of arteries. The results have a potential to assist in treatment of aneurysms without ischemic complications.

Parametry knihy

Zařazení knihy Knihy v angličtině Technology, engineering, agriculture Technology: general issues Engineering: general

1489

Oblíbené z jiného soudku



Osobní odběr Praha, Brno a 12903 dalších

Copyright ©2008-24 nejlevnejsi-knihy.cz Všechna práva vyhrazenaSoukromíCookies


Můj účet: Přihlásit se
Všechny knihy světa na jednom místě. Navíc za skvělé ceny.

Nákupní košík ( prázdný )

Vyzvednutí v Zásilkovně
zdarma nad 1 499 Kč.

Nacházíte se: