Mineralogical analysis and iron abundance estimation of the Moon using the SIR-2, HySl and M3 spectrometers on-board the lunar orbiter Chandrayaan-1 / Nejlevnější knihy
Mineralogical analysis and iron abundance estimation of the Moon using the SIR-2, HySl and M3 spectrometers on-board the lunar orbiter Chandrayaan-1

Kód: 01948440

Mineralogical analysis and iron abundance estimation of the Moon using the SIR-2, HySl and M3 spectrometers on-board the lunar orbiter Chandrayaan-1

Autor Megha U. Bhatt

The work presented in this thesis is focused on mineralogical studies of the Moon aiming to create maps of iron abundances. We used the data from visible to near-infrared (VIS-NIR) spectrometers on-board Chandrayaan-1 spacecraft, ... celý popis


Momentálně nedostupné

Informovat o naskladnění

Přidat mezi přání

Mohlo by se vám také líbit

Informovat o naskladnění knihy

Informovat o naskladnění knihy


Souhlas - Souhlasím se zasíláním obchodních sdělení a zpracováním osobních údajů k obchodním sdělením.

Zašleme vám zprávu jakmile knihu naskladníme

Zadejte do formuláře e-mailovou adresu a jakmile knihu naskladníme, zašleme vám o tom zprávu. Pohlídáme vše za vás.

Více informací o knize Mineralogical analysis and iron abundance estimation of the Moon using the SIR-2, HySl and M3 spectrometers on-board the lunar orbiter Chandrayaan-1

Anotace knihy

The work presented in this thesis is focused on mineralogical studies of the Moon aiming to create maps of iron abundances. We used the data from visible to near-infrared (VIS-NIR) spectrometers on-board Chandrayaan-1 spacecraft, with our major concentration on the Spectrometer InfraRed-2 (SIR-2) data. The SIR-2 on-ground and in-flight calibrations are discussed. The data reduction method for SIR-2 is explained and integration of the datasets obtained by SIR-2, HySI, and M3 instruments are discussed. We focused on the consistent lunar surface measurements collected by the SIR-2 instrument and used the SIR-2 data for the first time to derive the iron content of the Moons surface utilizing 2-m absorption band parameters. Using both 1-m and 2-m absorption band parameters we found a correlation of about 90% between iron abundances estimated by our method and actual laboratory-measured values (from Apollo and Luna datasets). The M3 data measured at the same UTC as the SIR-2 data are used for a comparative study. This study confirms that the 2-m absorption band can be used effectively to estimate the FeO wt% content of lunar surface materials through their NIR reflectance characteristics. Applications of this method would potentially be of great interest to those missions to the Moon and other planetary bodies carrying spectrometers in the wavelength range between 0.9 and 2.5 m.

Parametry knihy


Osobní odběr Praha, Brno a 12903 dalších

Copyright ©2008-24 nejlevnejsi-knihy.cz Všechna práva vyhrazenaSoukromíCookies


Můj účet: Přihlásit se
Všechny knihy světa na jednom místě. Navíc za skvělé ceny.

Nákupní košík ( prázdný )

Vyzvednutí v Zásilkovně
zdarma nad 1 499 Kč.

Nacházíte se: